型号 | 波长nm / OD | VLT | CE 认证 | 应用 |
2PL | 190-1200 | 15% | 2 NOIR 1 F CE | Flashlamp/IPL Non-Coherent |
3PL | 190-1200 | 7% | 3 NOIR I F CE | Flashlamp/IPL Non-Coherent |
5PL | 190-1200 | 2% | 6 NOIR I F CE | Flashlamp/IPL Non-Coherent |
ABL | 190-400 5+ 430-470 2+ | 77% | 0.1W 2*10E-5J 430-470 RB2 | Scientific Alignment |
AGR | 190-400 5+ 532 1.5+ 633-640 1+\\ | 31% | 0.01W 2*10E-6J 532 + 633-640 RB1 5-2.5 NOIR 1 S CE | Scientific Alignment |
AL3 | 180-395 5+ 395-540 3+ | 19% | 180-315 D LB6 + R LB4 >315-395 D LB4 + IR LB6 >395-540 DIR LB3 1W 2*10E-4J 488-540 RB3 | Scientific Alignment |
BD1 | 190-410 5+ | 66% | 190-315 D LB7 + IR LB4 >315-410 DIRM LB5 | Medical Dental Alignment |
BGR | 190-400 5+ 440-470 1.5+ 532 1.5+ 632-640 1+ | 29% | 0.01W 2*10E-6J 455-485 RB1 0.01W 2*10E-6J 532-538 RB1 0.01W 2*10E-6J 632-640 RB1 5-2.5 NOIR 1 S CE | Scientific Alignment Pilot |
CYN | 190-435 5+ 730-1085 5+ 755 7+ 1064 7+ | 36% | 190-315 D LB8 + R LB4 >315-430 D LB4 + IR LB6 730-1085 DIR LB5 745-765 DIR LB6 750-760 D LB6 + IRM LB7 1064 D LB6 + IRM LB7 | Ultrafast Medical |
DBD | 190-534 7+ 760-1090 5+ 790-850 7+ >850-960 6+ >960-1070 7+ |
|
|
|
92 | 190-400 5+ >400-593 2+ | 9% |
| Non-Coherent |
5032 | 190-400 4+ >400-480 3+ | 73% |
| Non-Coherent |
6032 | 190-535 3+ >535-540 2+ | 48% | 2-1.7 NOIR 1 S CE | Non-Coherent |
ABG | 180-400 5+ 445-470 + 520 2+ 524-532 3+ | 38% | 0.1W 2*10E-5J 445-470 RB2 1W 2*10E-4J 524-532 RB3 | Scientific Alignment Pilot |
AG2 | 190-400 5+ 524-532 2+ | 53% | 0.1W 2*10E-5J 524-532 RB2 | Scientific Alignment Pilot |
AG3 | 190-400 5+ 518-523 + 533-536 2+ 524-532 3+ | 47% | 0.1W 2*10E-5J 518-523 + 533-536 RB2 1W 2*10E-4J 524-532 RB3 | Scientific Alignment Pilot |
AHA | 190-400 5+ 510-670 1.5+ | 2% |
| Scientific Alignment |
AL2 | 190-380 5+ 400-532 2+ | 21% |
| Scientific Alignment |
AL4 | 405 + 488 1.5+ 400-514 1+ | 73% |
| Scientific Alignment |
ALX | 190-400 5+ 720-830 7+ 830-840 6+ | 25% | 720-830 I LB7 + R LB6 720-840 D LB5 >830-840 I LB6 + R LB5 | Medical Scientific |
ALY | 594 2.5+ | 43% |
| Scientific Alignment |
ARG | 180-532 7+ | 48% | 180-315 D LB7 + IR LB4 >315-532 DIRM LB6 | Industrial Ultrafast Medical Dental Scientific |
AXX | 190-400 6+ 720-810 7+
>810-830 5+ | 33% | 190-315 D LB8 + IR LB4 >315-390 DIRM LB6 720-810 D LB6 + IM LB7 + R LB5 >810-830 DIRM LB5 | Ultrafast Medical Scientific |
BDA | 190-375 5+ 405 2+ | 79% |
| Alignment |
CO2 | 190-360 5+ 10600 5+ | 93% |
| Industrial Medical Scientific |
DBY | 190-534 7+ 850-925 5+ 925-1070 6+ 960-1064 7+ | 35% | 180-315 D LB7 + R LB4 >315-534 D LB5 + IRM LB6 850-925 DIRM LB5 >925-980 D LB5 + IRM LB6 >980-1064 D LB6 + IRM LB7 >1064-1085 DIRM LB5 | Industrial Ultrafast Medical Scientific |
DD1 | 850-1090 3+ 915-1075 4+ 965-1065 5+ | 69% | 850-1090 DIR LB3 915-1075 DIR LB4 965-1065 DIR LB5 | Medical Dental Therapeutic |
DD2 |