Rugged and Reliable Column for Rapid Determination of Phosphoric and Citric Acids in ColasThis hydroxide-selective anion-
Rugged and Reliable Column for Rapid Determination of Phosphoric and Citric Acids in Colas
This hydroxide-selective anion-exchange column is specifically designed for the determination of phosphoric and citric acids in cola soft drinks. Its capacity and selectivity allows rapid analysis of these acids in less than 7 minutes.
Use with the Eluent Generator for simplified Reagent-Free IC operation.
The 3 mm i.d. configuration provides economical operation.
Combine with the ASRS®300 suppressor for low background and enhanced sensitivity.
Compatible with organic solvents.
The Fast Anion IIIA is optimized for a 30 °C operating temperature to ensure reproducible retention times in all environmental conditions. It is compatible with organic solvents to enhance analyte solubility, modify column selectivity, or allow effective column cleanup. The Fast Anion IIIA column is recommended for use with the Eluent Generator, requiring only a deionized water source to produce potassium hydroxide eluent.
The cola samples may require sample pretreatment with sonication to remove carbonation. Sample dilution of cola syrups is recommended prior to analysis to ensure optimum column life. These acids can be analyzed in less than 7 minutes using an isocratic potassium hydroxide eluent delivered by an Eluent Generator in combination with suppressed conductivity detection.
IonPac Fast Anion IIIA Anion-Exchange Column Specifications | |
---|---|
Dimensions | IonPac Fast Anion IIIA Analytical Column: 3 × 250 mm IonPac Fast Anion IIIA Guard Column: 3 × 50 mm |
Mobile phase compatibility | pH 0–14; 0–100% HPLC solvents |
Ion-exchange group | Functional Group: Alkanol quaternary ammonium ion |
Maximum operating pressure | 3000 psi |
Functional group characteristics | Hydrophobicity: Ultralow hydrophobic |
Capacity | 55 µeq (3×250 mm analytical column) 1.0 µeq (3×50 mm guard column) |
Column construction | PEEK with 10-32 threaded ferrule style end fittings. All components are nonmetallic. |
Substrate characteristics | Bead Diameter and Pore Size: 7.5 µm (3×250 mm); supermacroporous resin (2000 Å) 11 µm (3 × 50 mm); microporous resin (<10 Å) Cross-Linking (%DVB): 55% |
Determination of phosphoric acid in a cola soft drink using the Fast Anion IIIA column.
Determination of phosphoric and citric acid in a cola soft drink using the Fast Anion IIIA column.
Determination of phosphoric and citric acid in a diet cola soft drink using the Fast Anion IIIA column.
Rapid analysis of chloride and sulfate on an IonPac Fast Anion IIIA column.
Fast Gradient Separation of Anions in a Flavored Diet Cola Soft Drink on an IonPac Fast Anion IIIA Column.
Analytical Columns | |
---|---|
IonPac Fast Anion IIIA Analytical Column (3 x 250 mm) | 062964 |
Guard Columns | |
---|---|