400-6699-1175223

分析测试百科网 认证会员,请放心拨打!

首页> 产品展示> Acclaim PolarAdvantage II Reversed-Phase LC Column

诚信认证:

工商注册信息已核实!

LC Columns

Acclaim PolarAdvantage II Reversed-Phase LC Column

品牌 厂商性质 产地 货期
赛默飞 一般经销商 美国 订货

询底价
产品介绍

Complementary Selectivity and Enhanced Hydrolytic Stability

Acclaim®PolarAdvantage II (PA2) columns feature a patented bonding chemistry that provides enhanced hydrolytic stability from pH 1.5–10 and allows resolution of a wide variety of polar and nonpolar analytes. The Acclaim PA2 is compatible with 100% aqueous mobile phases and exhibits high reversed-phase capacity, with selectivity complementary to conventional C18 columns such as the Acclaim 120 C18. As with all Acclaim columns, the Acclaim PA2 is LC/MS-compatible.

  • Single-run analysis of polar and nonpolar analytes

  • Hydrolytically stable (pH 1.5–10)

  • Rugged column with high efficiency, symmetrical peak shapes even with basic and acidic compounds

  • Compatible with 100% aqueous mobile phases

  • High reversed-phase capacity with selectivity complementary to conventional C18 columns

Acclaim PA2 columns are compatible with 100% aqueous mobile phases, overcoming many of the limitations of conventional C8 and C18 reversed-phase columns. Conventional reversed-phase columns are unstable under these conditions and rapidly lose their ability to retain analytes.

Acclaim PA2 columns are available both in the 3- and 5-μm particle sizes and 4.6-, 3.0, and 2.1 mm- diameters, with and average pore diameter of 120Å. Acclaim PA2 is also available in 2.2 µm RSLC format (see Acclaim Rapid Separation LC (RSLC) Column section for more details). Acclaim PA2 may be used for some LC/MS applications.

Highly Stable Under Wide pH Range

The proprietary bonding of the Acclaim PA2 column resists hydrolytic attack by protecting the bonded phase at low pH. This column is highly stable with low pH.

In addition to low pH stability, although it is common to analyze basic compounds under high-pH conditions to reduce peak tailing, most polar-embedded phases are even less hydrolytically stable than conventional C18 columns. The Acclaim PA2 is specifically designed to withstand high pH conditions, making it a good choice for the separation of both basic and acidic analytes.


Acclaim®PA2: A Polar-Embedded Reversed-Phase Column with Selectivity Complementary to Conventional C18 ColumnsSpecifications
pH range1.5–10
End-cappedYes
Metal impurity (Na, Fe, Al)<10.0 ppm Total Metal
<3.0 ppm Individual Metal
Pore volume0.9–1.0 mL/g
Average pore diameter120 Å
Surface area300 m2/g
Temperature< 60oC
Starting materialUltrapure silica
Particle size3 and 5µm
Particle shapeSpherical
Particle size distribution (40/90)<1.3
Total carbon content17%
Carbon chain lengthC18


The Acclaim PA2 provides selectivity that is complementary to conventional C18 columns.

Omeprazole in anti-heartburn tablet.

Determination of energy drink ingredients.

Perfluoro-octanoic acid (PFOA) and perfluoro-octanesulfonic (PFOS) acid in tap water.


Analytical Columns
Acclaim 120, PA2, 3µm Analytical (2.1 x 50mm)077999
Acclaim 120, PA2, 3µm Analytical (2.1 x 100mm)077998
Acclaim PA2, 3 µm Analytical, (2.1 x 150 mm)063187
Acclaim 120, PA2, 3µm Analytical (2.1 x 250mm)077997
Acclaim PA2, 3µm Analytical, (3.0 x 50mm)068973
Acclaim 120, PA2, 3µm Analytical (3.0 x 100mm)078000
Acclaim PA2, 3 µm Analyitcal (3.0 x 150 mm)063705
Acclaim PA2, 3 µm, Analytical, (3.0 x 250 mm)070080
Acclaim PA2, 3 µm Analytical, (4.6 x 50 mm)063189
Acclaim 120, PA2, 3µm Analytical (4.6 x 100mm)078001
Acclaim PA2, 3 µm Analytical, (4.6 x 150 mm)063191
Acclaim PA2, 5 µm Analytical, (4.6 x 150 mm)063197
Acclaim PA2, 5 µm Analytical, (4.6 x 250 mm)063199
Guard Columns
Acclaim PA2, 5 µm Guard Cartridges, (4.6 x 10 mm), 2 ea (use V-2 Holder)069699
Acclaim PA2, 5µm Guard Cartridges (3 x 10mm), 2ea, requires holder 069580071985
Acclaim PA2, 5µm Guard Cartridges, (2.1 x 10mm), 2 ea; requires holder 069580069692
Acclaim SST Guard Cartridge Holder V-2069580
Acclaim Guard Kit (Holder and coupler) V-2069707
Guard to Analytical Column Coupler V-2074188
Acclaim RSLC PA2 Analytical Columns
Acclaim RSLC PA2, 3 µm Analytical (3.0 x 33 mm)066276
Acclaim PA2, 3µm Analytical, (3.0 x 50mm)068973
Acclaim RSLC PA2, 3 µm Analytical (3.0 x 75 mm)066277
Acclaim PA2, 3 µm Analyitcal (3.0 x 150 mm)063705
Acclaim RSLC PA2, 2.2µm Analytical, (2.1 x 30mm)071402
Acclaim RSLC PA2, 2.2µm Analytical (2.1 x 50 mm)068989
Acclaim RSLC PA2, 2.2µm Analytical (2.1 x 100 mm)068990
Acclaim RSLC PA2, 2.2µm Analytical, (2.1 x 150mm)071401
Acclaim RSLC PA2, 2.2µm Analytical (2.1 x 250mm)074814
Acclaim RSLC PA2, 2.2 µm Analytical, (3.0 x 100mm)071607
Acclaim RSLC PA2, 2.2 µm Analytical, (3.0 x 50mm)071608
Acclaim RSLC PA2, 2.2 µm Analytical, (3.0 x 30mm)071609


Acclaim PolarAdvantage II Reversed-Phase LC Column信息由上海希言科学仪器有限公司为您提供,如您想了解更多关于Acclaim PolarAdvantage II Reversed-Phase LC Column报价、型号、参数等信息,欢迎来电或留言咨询。

注:该产品未在中华人民共和国食品药品监督管理部门申请医疗器械注册和备案,不可用于临床诊断或治疗等相关用途