Acclaim PolarAdvantage II Reversed-Phase LC Column
品牌 | 厂商性质 | 产地 | 货期 |
---|---|---|---|
赛默飞 | 一般经销商 | 美国 | 订货 |
Complementary Selectivity and Enhanced Hydrolytic Stability
Acclaim®PolarAdvantage II (PA2) columns feature a patented bonding chemistry that provides enhanced hydrolytic stability from pH 1.5–10 and allows resolution of a wide variety of polar and nonpolar analytes. The Acclaim PA2 is compatible with 100% aqueous mobile phases and exhibits high reversed-phase capacity, with selectivity complementary to conventional C18 columns such as the Acclaim 120 C18. As with all Acclaim columns, the Acclaim PA2 is LC/MS-compatible.
Single-run analysis of polar and nonpolar analytes
Hydrolytically stable (pH 1.5–10)
Rugged column with high efficiency, symmetrical peak shapes even with basic and acidic compounds
Compatible with 100% aqueous mobile phases
High reversed-phase capacity with selectivity complementary to conventional C18 columns
Acclaim PA2 columns are compatible with 100% aqueous mobile phases, overcoming many of the limitations of conventional C8 and C18 reversed-phase columns. Conventional reversed-phase columns are unstable under these conditions and rapidly lose their ability to retain analytes.
Acclaim PA2 columns are available both in the 3- and 5-μm particle sizes and 4.6-, 3.0, and 2.1 mm- diameters, with and average pore diameter of 120Å. Acclaim PA2 is also available in 2.2 µm RSLC format (see Acclaim Rapid Separation LC (RSLC) Column section for more details). Acclaim PA2 may be used for some LC/MS applications.
Highly Stable Under Wide pH Range
The proprietary bonding of the Acclaim PA2 column resists hydrolytic attack by protecting the bonded phase at low pH. This column is highly stable with low pH.
In addition to low pH stability, although it is common to analyze basic compounds under high-pH conditions to reduce peak tailing, most polar-embedded phases are even less hydrolytically stable than conventional C18 columns. The Acclaim PA2 is specifically designed to withstand high pH conditions, making it a good choice for the separation of both basic and acidic analytes.
Acclaim®PA2: A Polar-Embedded Reversed-Phase Column with Selectivity Complementary to Conventional C18 ColumnsSpecifications | |
---|---|
pH range | 1.5–10 |
End-capped | Yes |
Metal impurity (Na, Fe, Al) | <10.0 ppm Total Metal <3.0 ppm Individual Metal |
Pore volume | 0.9–1.0 mL/g |
Average pore diameter | 120 Å |
Surface area | 300 m2/g |
Temperature | < 60oC |
Starting material | Ultrapure silica |
Particle size | 3 and 5µm |
Particle shape | Spherical |
Particle size distribution (40/90) | <1.3 |
Total carbon content | 17% |
Carbon chain length | C18 |
The Acclaim PA2 provides selectivity that is complementary to conventional C18 columns.
Omeprazole in anti-heartburn tablet.
Determination of energy drink ingredients.
Perfluoro-octanoic acid (PFOA) and perfluoro-octanesulfonic (PFOS) acid in tap water.
Analytical Columns | |
---|---|
Acclaim 120, PA2, 3µm Analytical (2.1 x 50mm) | 077999 |
Acclaim 120, PA2, 3µm Analytical (2.1 x 100mm) | 077998 |
Acclaim PA2, 3 µm Analytical, (2.1 x 150 mm) | 063187 |
Acclaim 120, PA2, 3µm Analytical (2.1 x 250mm) | 077997 |
Acclaim PA2, 3µm Analytical, (3.0 x 50mm) | 068973 |
Acclaim 120, PA2, 3µm Analytical (3.0 x 100mm) | 078000 |
Acclaim PA2, 3 µm Analyitcal (3.0 x 150 mm) | 063705 |
Acclaim PA2, 3 µm, Analytical, (3.0 x 250 mm) | 070080 |
Acclaim PA2, 3 µm Analytical, (4.6 x 50 mm) | 063189 |
Acclaim 120, PA2, 3µm Analytical (4.6 x 100mm) | 078001 |
Acclaim PA2, 3 µm Analytical, (4.6 x 150 mm) | 063191 |
Acclaim PA2, 5 µm Analytical, (4.6 x 150 mm) | 063197 |
Acclaim PA2, 5 µm Analytical, (4.6 x 250 mm) | 063199 |
Guard Columns | |
---|---|
Acclaim PA2, 5 µm Guard Cartridges, (4.6 x 10 mm), 2 ea (use V-2 Holder) | 069699 |
Acclaim PA2, 5µm Guard Cartridges (3 x 10mm), 2ea, requires holder 069580 | 071985 |
Acclaim PA2, 5µm Guard Cartridges, (2.1 x 10mm), 2 ea; requires holder 069580 | 069692 |
Acclaim SST Guard Cartridge Holder V-2 | 069580 |
Acclaim Guard Kit (Holder and coupler) V-2 | 069707 |
Guard to Analytical Column Coupler V-2 | 074188 |
Acclaim RSLC PA2 Analytical Columns | |
---|---|
Acclaim RSLC PA2, 3 µm Analytical (3.0 x 33 mm) | 066276 |
Acclaim PA2, 3µm Analytical, (3.0 x 50mm) | 068973 |
Acclaim RSLC PA2, 3 µm Analytical (3.0 x 75 mm) | 066277 |
Acclaim PA2, 3 µm Analyitcal (3.0 x 150 mm) | 063705 |
Acclaim RSLC PA2, 2.2µm Analytical, (2.1 x 30mm) | 071402 |
Acclaim RSLC PA2, 2.2µm Analytical (2.1 x 50 mm) | 068989 |
Acclaim RSLC PA2, 2.2µm Analytical (2.1 x 100 mm) | 068990 |
Acclaim RSLC PA2, 2.2µm Analytical, (2.1 x 150mm) | 071401 |
Acclaim RSLC PA2, 2.2µm Analytical (2.1 x 250mm) | 074814 |
Acclaim RSLC PA2, 2.2 µm Analytical, (3.0 x 100mm) | 071607 |
Acclaim RSLC PA2, 2.2 µm Analytical, (3.0 x 50mm) | 071608 |
Acclaim RSLC PA2, 2.2 µm Analytical, (3.0 x 30mm) | 071609 |
Acclaim PolarAdvantage II Reversed-Phase LC Column信息由上海希言科学仪器有限公司为您提供,如您想了解更多关于Acclaim PolarAdvantage II Reversed-Phase LC Column报价、型号、参数等信息,欢迎来电或留言咨询。
注:该产品未在中华人民共和国食品药品监督管理部门申请医疗器械注册和备案,不可用于临床诊断或治疗等相关用途