咨询列表
X
头像

客服中心

如果企业客服不在线,也可拨打400电话联系。或者发布求购信息

400-6699-117 转 1000
发布求购 实验百科采购-随时微信沟通
扫码关注
实验采购百科

400-6699-1171000

分析测试百科网 认证会员,请放心拨打!

首页> 产品展示> 赛默飞Thermo Dionex IonPac AS27 Hydroxide-Selective Anion-Exchange Column离子色谱IC柱

普通会员

诚信认证:

工商注册信息已核实!

IC

赛默飞Thermo Dionex IonPac AS27 Hydroxide-Selective Anion-Exchange Column离子色谱IC柱

品牌 厂商性质 产地 货期
赛默飞 一般经销商 美国 现货

性能特点

离子色谱IC柱

在线咨询 询底价
产品介绍

Trace Analysis of Oxyhalides and Inorganic Anions in Drinking Water Preserved with Ethylenediamine

Achieve high resolution separations of trace oxyhalides and inorganic anions in drinking water using the Thermo ScientificDionexIonPacAS27 hydroxide-selective anion-exchange column. The selectivity of the Dionex IonPac AS27 column has been optimized for trace level analysis of bromate in the presence of ppm levels of ethylenediamine (EDA). EDA is used as a preservative in some drinking water samples and can cause interference of early eluting peaks, including bromate. The high resolution, high capacity and selectivity of the Dionex IonPac AS27 column allows the determination of trace bromate in drinking water without sample pretreatment or preconcentration. The Dionex IonPac AS27 columns meets the performance requirements of US EPA Methods 300.0 and 300.1.

The Dionex IonPac AS27 column is available in three formats: 4 × 250 mm, 2 × 250 mm and 0.4 × 250 mm.The Dionex IonPac AS27 Capillary Column is packed with the same material as the equivalent standard bore version (providing the same performance as a 4 mm column), but requires only 1/100th the eluent flow rate.The capillary format provides the advantage of significantly reduced eluent consumption, which helps reduce operating costs.

  • Optimized for analysis of trace bromate in drinking water preserved with EDA

  • High capacity: 220 μeq per column (4 × 250 mm)

  • Meets or exceeds performance requirements of US EPA Methods 300.0 and 300.1

  • Column selectivity is optimized for 30 °C operating temperature

  • Compatible with organic solvents

The Dionex IonPac AS27 column is designed for the analysis of oxyhalides and common inorganic anions including fluoride, chlorite, bromate, chloride, nitrite, bromide, chlorate, nitrate, phosphate, and sulfate in drinking water, groundwater, wastewater, and other diverse sample matrices. The Dionex IonPac AS27 column allows analysis of most drinking water preserved with EDA without sample pretreatment or preconcentration. This column is ideally used with an RFIC system for automatic eluent generation.

The key application for the Dionex IonPac AS27 column is the determination of trace bromate in drinking water matrices that have been preserved with EDA using a potassium hydroxide gradient with suppressed conductivity detection. The selectivity of the Dionex IonPac AS27 column ensures that bromate can be quantified at low μg/L concentrations using suppressed conductivity detection even in the presence of very high concentrations of chloride, sulfate, and carbonate as well as EDA.

The Dionex IonPac AS27 column has similar selectivity and capacity compared to the Dionex IonPac AS19 column and most applications can be performed on either column. However, for samples preserved with EDA, the Dionex IonPac AS27 column is recommended.

The Dionex IonPac AS27 column produces under 3000 psi at the standard flow rates and can be operated on any Dionex IC system, such as the Thermo ScientificDionexICS-5000+HPICor the Thermo Scientific Dionex ICS-4000 Capillary HPIC system.

Note: Use the Thermo ScientificDionexAERS500 Anion Electrolytically Regenerated Suppressor with the Dionex IonPac AS27 column for eluent suppression.


Dionex IonPac AS27 Anion-Exchange Column Specifications
DimensionsDionex IonPac AS27 Analytical Column:
2×250 mm and 4 × 250 mm
Dionex IonPac AG27 Guard Column:
2 × 50 mm and 4 × 50 mm
Dionex IonPac AS27 Capillary Column:
0.4 × 250 mm
Dionex IonPac AG27 Capillary Guard Column:
0.4 × 50 mm
Maximum operating pressure3000 psi
Ion-exchange groupFunctional Group: Alkanol quaternary ammonium ion
Functional group characteristicsUltralow hydrophobicity
Capacity2.2µeq (0.4 × 250 mm capillary column)
0.05µeq* (0.4 × 50 mm capillary guard column)
55µeq (2 × 250 mm analytical column)
1.25 µeq* (2 × 50 mm guard column)
220µeq (4 × 250 mm analytical column)
5µeq* (4 × 50 mm guard column)
*Guards are packed with a low-capacity microporous resin.
Column constructionPEEK with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
Substrate characteristicsBead Diameter and Pore Size: 6.5µm (0.4 x 250, 2×250 and 4 × 250 mm);
super macroporous resin (2000 Å)
10 µm (0.4 x 50, 2 × 50 and 4 × 50 mm);
microporous resin (<1 Å)
Cross-Linking (%DVB): 55%
Mobile phase compatibilitypH 0–14; 0–100% HPLC solvents



Determination of trace bromate in the presence of 50 ppm ethylenediamine in a municipal drinking water sample using the Dionex IonPac AS27 column.

Determination of oxyhalides and common inorganic anions using the Dionex IonPac AS27 column.

Determination of inorganic anions and trace level oxyhalides in a simulated drinking water using the Dionex IonPac AS27 column.



Separation of 24 anions using the Dionex IonPac AS27 column.


Separation of inorganic anions and oxyhalides using the Dionex IonPac AS27 column with and without a guard column.


Analytical Columns
Dionex IonPac AS27 Analytical Column (4 × 250 mm)088437
Dionex IonPac AS27 Analytical Column (2 × 250 mm)088439
Dionex IonPac AS27 Capillary Column (0.4 × 250 mm)088441
Guard Columns
Dionex IonPac AG27 Guard Column (4 × 50 mm)088438
Dionex IonPac AG27 Guard Column (2 × 50 mm)088440
Dionex IonPac AG27 Capillary Guard Column (0.4 × 50 mm)088442


赛默飞Thermo Dionex IonPac AS27 Hydroxide-Selective Anion-Exchange Column离子色谱IC柱信息由上海希言科学仪器有限公司为您提供,如您想了解更多关于赛默飞Thermo Dionex IonPac AS27 Hydroxide-Selective Anion-Exchange Column离子色谱IC柱报价、型号、参数等信息,欢迎来电或留言咨询。

注:该产品未在中华人民共和国食品药品监督管理部门申请医疗器械注册和备案,不可用于临床诊断或治疗等相关用途