产品介绍

Fast, pH-Stable Separation of Oligosaccharides

A variety of HPLC approaches are proposed for characterizing oligosaccharides, but many prove inadequate for separating complex mixtures and are limited by a lack of specificity and high limits of detection. Dionex has developed an improved HPLC technique for carbohydrate analysis based on anion-exchange chromatography coupled with pulsed amperometric detection. This technique provides high-resolution separations with sensitive and specific detection, without derivatization.

  • Sensitive, direct detection with no derivatization, using pulsed amperometric detection

  • Very high-efficiency separations

  • Separations based on size, charge, degree of branching, and linkage isomerism

  • Low flow rate saves on eluent consumption

  • Does not require derivatization

CarboPac®PA200 columns are packed with a hydrophobic, polymeric, pellicular anion-exchange resin stable over the range of pH 0–14. The unique pH-stability of the packing material allows the use of eluent compositions that are conducive to anodic oxidation of carbohydrates at gold electrodes.


CarboPac PA200 Column for High-Resolution Oligosaccharide Separations Specifications
DimensionsCarboPac®PA200 Analytical Column:
3×250 mm
CarboPac PA200 Guard Column:
3×50 mm
Maximum operating pressure4000 psi (27.9 MPa)
Temperature range6–60°C
Recommended operating temperature: controlled ambient
Typical operating conditions2700 psi at 0.5 mL/min (analytical and guard columns)
Recommended flow rate: 0.5 mL/min
Mobile phase compatibilitypH 0–14; 100% compatible with common organic solvents.
Ionic form eluents: sodium acetate and sodium hydroxide only.
Resin composition5.5 µm-diameter ethylvinylbenzene/divinylbenzene substrate (55% cross-linked) agglomerated with 43 nm MicroBead®quaternary amine functionalized latex (6% crosslinked)
Anion-exchange capacityApproximately 35µeq/column (3×250 mm analytical column)
Column constructionPEEKwith 10-32 threaded ferrule-style end fittings.
All components are nonmetallic


The CarboPac PA200 column is the latest addition to the CarboPac family of columns for carbohydrate separations. This column has been specially developed to provide high resolution separations of charged and neutral oligosaccharides and is the recommended column for these applications. The CarboPac PA200 columns are packed with a hydrophobic, polymeric, pellicular anion exchange resin stable over the range of pH 0–14. This unique pH-stability of the packing material allows the use of eluent compositions that are conducive to anodic oxidation of carbohydrates at gold electrodes.


Resin Characteristics:

Particle Size:5.5 µm

Pore Size: microporous (< 10 Å)

Cross-linking:55%

Ion exchange capacity: 35 µeq per column

Latex Characteristics:

Functional Group:quaternary ammonium ion

Latex Diameter: 43 nm

Latex Cross-linking: 6%


Typical Operating Parameters:

pH range: 0–14

Temperature Limit: 4–60 °C

Pressure Limit:3500 psi

Organic Solvent Limit: 100% compatible

Typical eluents: High purity water (18.2 megohm-cm), sodium hydroxide, sodium acetate


Guard Columns
CarboPac PA200 Guard Column (3 x 50 mm)062895
Analytical Columns
CarboPac PA200 Analytical Column (3 x 250 mm)062896


CarboPac PA200 Carbohydrate Column信息由上海希言科学仪器有限公司为您提供,如您想了解更多关于CarboPac PA200 Carbohydrate Column报价、型号、参数等信息,欢迎来电或留言咨询。

注:该产品未在中华人民共和国食品药品监督管理部门申请医疗器械注册和备案,不可用于临床诊断或治疗等相关用途