Fast, Sensitive Mono- and Disaccharide Analysis

The Thermo Scientific Dionex CarboPacPA20 column line has been expanded to include a new 0.4 × 150 mm capillary column and a new Dionex CarboPac PA20 Fast Sialic Acid column.

As with all CarboPac PA20 columns, the new capillary format provides high-resolution separations of mono- and disaccharides with no need for derivatization. The Dionex CarboPac PA20, 0.4 × 150 mm format offers the additional advantages of higher mass sensitivity, lower sample amount requirements, and significantly lower solvent use.

The new Dionex CarboPac PA20 Fast Sialic Acid column is ideally suited for the fast analysis of sialic acids in glycoprotein acid hydrolyzates. The Dionex CarboPac PA20 Fast Sialic Acid column accelerates sialic acid determination allowing sample analysis in less than five minutes. The Dionex CarboPac PA20 Fast Sialic Acid column is packed with the same hydrophobic, polymeric, pellicular anion exchange resin as the Dionex CarboPac PA20 column, but in a 3 x 30 mm column format.

The Dionex CarboPac PA20 is a strong anion-exchange column that provides high-resolution separations of mono- and disaccharides with no need for derivatization. This column provides baseline resolution between the six monosaccharides commonly found in mammalian glycoproteins over a wide range of eluent concentrations. The Dionex CarboPac PA20 provides slightly different selectivity from either the Dionex CarboPac PA1 or Dionex CarboPac PA10, making it an attractive choice for separating difficult peak pairs.

  • The column of choice for high-sensitivity monosaccharide analyses

  • Highly efficient separations with good resolution between neighboring peaks

  • Fast analysis—less than 10 min

  • Optimized resolution of glucosamine/galactose and glucose/mannose peak pairs

  • Lower eluent consumption

  • Does not require derivatization

The Dionex CarboPac PA20 consists of 6.5 µm-diameter nonporous beads covered with a fine latex of functionalized Thermo Scientific Dionex MicroBeadresin. This pellicular resin structure permits excellent mass transfer, resulting in high-resolution chromatography and rapid re-equilibration. The performance of each column is verified with a Thermo Scientific Dionex MonoStandard.


Dionex CarboPac PA20 Column for Fast Monosaccharide Analysis Specifications
DimensionsDionex CarboPacPA20 Analytical Column:
3×150 mm
Dionex CarboPac PA20 Capillary Column:
0.4 × 150 mm
Dionex CarboPac PA20 Fast Sialic Acid Column:
3 × 30 mm
Dionex CarboPac PA20 Guard Column:
3 × 30 mm
Maximum operating pressure3000 psi (21 MPa)
Temperature range4–60 °C
Recommended operating temperature: 30 °C
Typical operating conditionsTest procedure: Baseline resolution of fucose, galactosamine, glucosamine, galactose, glucose, mannose.
Dionex CarboPac PA20 Analytical Column recommended flow rate: 0.5 mL/min
Dionex CarboPac PA20 Capillary Column recommended flow rate: 8 µL/min
Dionex CarboPac PA20 Fast Sialic Acid Column recommended flow rate: 0.5 mL/min
Mobile phase compatibilitypH 0–14;
100% compatible with common HPLC solvents and 100% water.
Ionic form eluents: sodium hydroxide, sodium acetate.
Resin composition6.5 µm-diameter substrate (ethylvinylbenzene 55% crosslinked with divinylbenzene) agglomerated with 130 nm MicroBeaddifunctional quaternary ammonium ion (5% crosslinked).
Anion-exchange capacityApproximately 65 µeq/column (3×150 mm analytical column)
Approximately 1.16 µeq/column (0.4×150 mm capillary column)
Approximately 13 µeq/column (0.3 x 30 mm Fast Sialic Acid column)
Column constructionPEEKwith 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.



Analysis of chocolate syrup using the CarboPac PA20.

Sialic acid analysis of bovine fetuin.

Effect of hydroxide concentration on monosaccharide elution times.

Monosaccharide analysis of rabbit serum using the CarboPac PA20 column.

Profiling MAb hydrolysate on the CarboPac PA20 column, with and without an AminoTrap®precolumn.


Analytical Columns
CarboPac PA20 Analytical Column (3 x 150 mm)060142
CarboPac PA20 Capillary Column (0.4 x 150 mm)072072
CarboPac PA20 Fast Sialic Column (3 x 30 mm)076381
Guard Columns
CarboPac PA20 Guard Column (3 x 30 mm)060144
Borate Trap Column047078
Amino Trap Column (3 x 30 mm)060146
CarboPac PA20 Capillary Guard Column (0.4 x 35 mm)072073


赛默飞Thermo CarboPac PA20 Carbohydrate Column离子色谱IC柱信息由上海希言科学仪器有限公司为您提供,如您想了解更多关于赛默飞Thermo CarboPac PA20 Carbohydrate Column离子色谱IC柱报价、型号、参数等信息,欢迎来电或留言咨询。

注:该产品未在中华人民共和国食品药品监督管理部门申请医疗器械注册和备案,不可用于临床诊断或治疗等相关用途