赛默飞Thermo CarboPac PA1 Carbohydrate Column离子色谱IC柱
品牌 | 厂商性质 | 产地 | 货期 |
---|---|---|---|
赛默飞 | 一般经销商 | 美国 | 现货 |
性能特点
离子色谱IC柱
Ideal Column for the Separation of Neutral and Acidic Monosaccharides
The CarboPac®PA1 is an anion-exchange column for the separation of mono-, disaccharides, and specific oligosaccharides using an isocratic eluent. Sialic acid analysis has also been demonstrated on this column.
General-purpose column for isocratic determination of monosaccharides and disaccharides
Detection by pulsed amperometric detection; no derivatization needed
Approved for use in a variety of official methods for the analysis of foods
The unique MicroBead™pellicular structure of the CarboPac PA1 resin gives it stability from pH 0–14 at all concentrations of buffer salts. The pellicular resin structure allows excellent mass transfer resulting in fast gradient reequilibration.
The CarboPac PA1 column is used with pulsed amperometric detection; no derivatization is required. Sensitivity on the PA1 is not as high as with the CarboPac PA20 or PA10 for monosaccharide analysis. Thus the CarboPac PA1 is well suited for the analysis of foods for nutritional labeling. The CarboPac PA1 has been approved for use in a number of official methods.
CarboPac PA1 Column for Routine Carbohydrate AnalysisSpecifications | |
---|---|
Dimensions | CarboPac PA1 Analytical Column: 4×250 mm and 2 × 250 mm CarboPac PA1 Guard Column: 4 × 50 mm and 2 × 50 mm CarboPac PA1 Semipreparative Column: 22 × 250 mm |
Maximum operating pressure | 4000 psi (27.9 MPa) |
Temperature range | 4–55 °C Recommended operating temperature: ambient |
Typical operating conditions | 1500 psi at 1.0 mL/min (analytical and guard columns) Recommended flow rate: 1.0 mL/min (for 4×250 mm) |
Mobile phase compatibility | pH 0–14; up to 2% of common HPLC solvents. Acetate or hydroxide eluents only. |
Resin composition | 10-µm-diameter substrate (polystyrene 2% cross-linked with divinylbenzene) agglomerated with 500-nm MicroBead quaternary ammonium functionalized latex (5% cross-linked). |
Anion-exchange capacity | Approximately 100 µeq/column (4×250 mm analytical column) |
Column construction | PEEK with 10-32 threaded-ferrule-style end fittings. All components are nonmetallic. |
Chromatographic analysis of purified inulin.
Analysis of mono- and diphosphorylated monosaccharides on the CarboPac PA1.
Isocratic Separation of Sugars Found in Sugarcane Molasses Using the CarboPac PA1 Column.
Analytical Columns | |
---|---|
CarboPac PA1 Analytical Column (2 x 250 mm) | 057178 |
CarboPac PA1 Analytical Column (4 X 250 mm) | 035391 |
CarboPac PA1 Semi-Preparative Column (9 x 250 mm) | 039686 |
CarboPac PA1 Semi-Preparative Column (22 x 250 mm) | SP2866 |
Guard Columns | |
---|---|
CarboPac PA1 Guard Column (2 x 50 mm) | 057179 |
CarboPac PA1 Guard Column (4 x 50 mm) | 043096 |
CarboPac PA1 Guard (9 x 50 mm) | 063501 |
赛默飞Thermo CarboPac PA1 Carbohydrate Column离子色谱IC柱信息由上海希言科学仪器有限公司为您提供,如您想了解更多关于赛默飞Thermo CarboPac PA1 Carbohydrate Column离子色谱IC柱报价、型号、参数等信息,欢迎来电或留言咨询。