Acclaim PolarAdvantage: Rugged 极性键合反相柱,用于分析极性和非极性成分
  The Acclaim® PolarAdvantage (PA) 柱拥有专利的键合相技术,极性磺胺基团键合到硅胶基质表面,这种特性加强了柱子水解稳定性,能同时保留极性和非极性分析物。该色谱柱兼容100%水相,同时兼有反相柱特点,与LC-MS兼容。
 

Sulfonamide-Embedded Reversed-Phase Columns for Separating Polar Compounds

Acclaim® Polar Advantage (PA C16) columns feature a patented bonding chemistry that incorporates a polar sulfonamide group near the surface of the silica particle. This unique chemistry provides good hydrolytic stability and allows a single column to resolve a wide variety of polar and nonpolar analytes. The Acclaim PA is compatible with 100% aqueous mobile phases and supports LC/MS analysis.

  • Low silanol activity for excellent peak shape with basic compounds
  • Novel polar-embedded column chemistry
  • Compatible with 0–100% organic solvent mobile phases
  • High selectivity for hydrophobic aromatic compounds
  • Wide range of applications

Conventional C18 phases are not compatible with highly aqueous mobile phases, due to dewetting. The Acclaim PA column by design has a mildly hydrophilic surface, which remains in contact with aqueous-only mobile phases, negating the problems of dewetting common with conventional reversed-phase columns.

Acclaim PA columns are available both in 3 and 5 μm particle sizes and 4.6, 3.0, and 2.1 mm diameters, with an average pore diameter of 120 Å. Acclaim PA is also available in 2.2µm RSLC format (see Acclaim Rapid Separation LC (RSLC) Columns section for more details). Acclaim PA may be used for LC/MS applications. 

Applications

The Acclaim PA column can be used in a wide range of applications in pharmaceutical, environmental, food testing, and product-quality testing. These columns also give efficient separations with good peak shapes for compounds of life science (nucleic acid and bases) and pharmaceutical interest (sulfonamides) using highly aqueous mobile phases.

Acclaim PolarAdvantage: Rugged Polar-Embedded Reversed-Phase Columns for the Analysis of Polar and Nonpolar Compounds  Specifications
Surface coverage 2.7 mmol/m2
End-capped Yes
Metal impurity (Na, Fe, Al) <10.0 ppm Total Metal
<3.0 ppm Individual Metal
Pore volume 1.0 mL/g
Average pore diameter 120 Å
Surface area 300 m2/g
pH range 2–8
Temperature <60 °C
Starting material Ultrapure silica
Particle size 3 and 5 µ
Particle shape Spherical
Particle size distribution (40/90) <1.3
Total carbon content 17%


订购信息:
Analytical Columns
Acclaim PA, 3 µm Analytical (2.1 x 100 mm) 061316
Acclaim PA, 3 µm Analytical (2.1 x 150 mm) 061317
Acclaim 120, PA, 3µm Analytical (2.1 x 250mm) 076215
Acclaim PA, 3µm Analytical, (3.0 x 50mm) 068972
Acclaim 120, PA, 3µm Analytical (3.0 x 100mm) 076214
Acclaim PA, 3 µm Analyitcal (3.0 x 150 mm) 063693
Acclaim PA, 3 µm, Analytical, (3.0 x 250 mm) 070079
Acclaim PA, 3 µm Analytical (4.6 x 150 mm) 061318
Acclaim 120, PA, 3µm Analytical (4.6 x 100mm) 076216
Acclaim PA, 5 µm Analytical (4.6 x 50 mm) 061319
Acclaim PA, 5 µm Analytical (4.6 x 150 mm) 061320
Acclaim PA, 5 µm Analytical (4.6 x 250 mm) 061321
Guard Columns
Acclaim PA, 5µm,2mm Guard Cartridges, (2.1 x 10mm), 2 ea; requires holder 069580 069691
Acclaim PA, 5µm Guard Cartridges (3 x 10mm), 2ea, requires holder 069580 071983
Acclaim PA, 5 µm Guard Cartridges, (4.6 x 10 mm), 2 ea (use V-2 Holder) 069698
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188
Acclaim RSLC PA Analytical Columns
Acclaim RSLC PA, 3 µm Analytical (3.0 x 33 mm) 066274
Acclaim PA, 3µm Analytical, (3.0 x 50mm) 068972
Acclaim RSLC PA, 3 µm Analytical (3.0 x 75 mm) 066275
Acclaim PA, 3 µm Analyitcal (3.0 x 150 mm) 063693
Acclaim RSLC PA, 2.2µm, 2.1 x 50 mm 072622
Acclaim RSLC PA, 2.2µm, 2.1 x 30 mm 072621
Acclaim RSLC PA, 2.2µm, 2.1 x 100 mm 072623
Acclaim RSLC PA, 2.2µm, 2.1 x 150 mm 072624
Acclaim RSLC PA, 2.2µm Analytical (2.1 x 250mm) 074813
Acclaim RSLC PA, 2.2µm, 3 x 30mm 072625
Acclaim RSLC PA, 2.2µm, 3 x 100mm 072627
Acclaim RSLC PA, 2.2µm, 3 x 50mm 072626

应用谱图:

Fat-soluble vitamins and carotenoids in a vitamin tablet.

 

Loratidine and pseudo-ephedrine in a time-release tablet.

 

LC separation of nitrosamines, as specified in EPA 8270.

 

Phospholipids in egg lecithin

AcclaimPolarAdvantage(PAC16):Rugged极性键合反相柱,用于分析极性和非极性成分极性键合反相柱信息由北京携测技术有限公司为您提供,如您想了解更多关于AcclaimPolarAdvantage(PAC16):Rugged极性键合反相柱,用于分析极性和非极性成分极性键合反相柱报价、型号、参数等信息,欢迎来电或留言咨询。

注:该产品未在中华人民共和国食品药品监督管理部门申请医疗器械注册和备案,不可用于临床诊断或治疗等相关用途

店铺推荐
  • 品牌:沃特世
    ACQUITYUPLCBEH色谱柱

    ACQUITYUPLCBEH色谱柱

    询价
  • 品牌:沃特世
    ACQUITYUPLCCSH色谱柱

    ACQUITYUPLCCSH色谱柱

    询价
  • 品牌:沃特世
    ACQUITYUPLCHSS色谱柱

    ACQUITYUPLCHSS色谱柱

    询价
  • 品牌:沃特世
    ACQUITYUPLC色谱柱方法方法包

    ACQUITYUPLC色谱柱方法方法包

    询价
  • 品牌:沃特世
    ACQUITYUPLC方法转换包

    ACQUITYUPLC方法转换包

    询价
  • 品牌:沃特世
    ACQUITYUPLC方法验证包

    ACQUITYUPLC方法验证包

    询价