400-6699-1171000

分析测试百科网 认证会员,请放心拨打!

首页> 产品展示> AcclaimPolarAdvantageII(PA2)反相分析柱
普通会员

诚信认证:

工商注册信息已核实!

快速导航
产品分类
多种键合相综合

AcclaimPolarAdvantageII(PA2)反相分析柱

品牌 厂商性质 产地 货期
赛默飞 一般经销商 美国 现货

在线咨询 询底价
产品介绍

Acclaim PA2: 拥有超强水解稳定性的内嵌极性基团柱,补充了传统反相C18色谱柱选择性
  The Acclaim PolarAdvantage II (PA2)拥有专利的键合相技术,将极性磺胺基团键合到硅胶基质表面。在PH1.5-10范围内能加强水解稳定性保证柱子能同时分离极性和非极性分析物。Acclaim PA2 能适应100%水相,并且保持反相柱的选择性,补充了反相C18的选择性,如Acclaim 120 C18柱。同所有Acclaim系列色谱柱一样,Acclaim PA2具有LC/MS适应性。
 
Complementary selectivity and enhanced hydrolytic stability

  Acclaim Polar Advantage II (PA2) columns feature a patented bonding chemistry that provides enhanced hydrolytic stability from pH 1.5–10 and allows resolution of a wide variety of polar
and nonpolar analytes. The Acclaim PA2 is compatible with 100% aqueous mobile phases and exhibits high reversed-phase capacity, with selectivity complementary to conventional C18 columns such as the Acclaim 120 C18. As with all Acclaim columns, the Acclaim PA2 is LC/MS-compatible.
• Single-run analysis of polar and nonpolar analytes
• Hydrolytically stable (pH 1.5–10)
• Rugged column with high efficiency, symmetrical peak shapes even with basic and acidic compounds
• Compatible with 100% aqueous mobile phases
• High reversed-phase capacity with selectivity complementary to conventional C18 columns
  Acclaim PA2 columns are compatible with 100% aqueous mobile phases, overcoming many of the limitations of conventional C8 and C18 reversed-phase columns. Conventional reversedphase columns are unstable under these conditions and rapidly lose their ability to retain analytes.
  Acclaim PA2 columns are available both in the 3- and 5-μm particle sizes and 4.6-, 3.0, and 2.1 mm- diameters, with and average pore diameter of 120Å. Acclaim PA2 may be used for some LC/MS applications. These columns are available for fast LC; refer to the RSLC section.

Acclaim PA2: A Polar-Embedded Reversed-Phase Column with Selectivity Complementary to Conventional C18 Columns  Specifications
pH range 1.5–10
End-capped Yes
Metal impurity (Na, Fe, Al) <10.0 ppm Total Metal
<3.0 ppm Individual Metal
Pore volume 0.9–1.0 mL/g
Average pore diameter 120 Å
Surface area 300 m2/g
Temperature < 60 oC
Starting material Ultrapure silica
Particle size 3 and 5  µm
Particle shape Spherical
Particle size distribution (40/90) <1.3
Total carbon content 17%
Carbon chain length C18

订购信息:
Analytical Columns
Acclaim 120, PA2, 3µm Analytical (2.1 x 50mm) 077999
Acclaim 120, PA2, 3µm Analytical (2.1 x 100mm) 077998
Acclaim PA2, 3 µm Analytical, (2.1 x 150 mm) 063187
Acclaim 120, PA2, 3µm Analytical (2.1 x 250mm) 077997
Acclaim PA2, 3µm Analytical, (3.0 x 50mm) 068973
Acclaim 120, PA2, 3µm Analytical (3.0 x 100mm) 078000
Acclaim PA2, 3 µm Analyitcal (3.0 x 150 mm) 063705
Acclaim PA2, 3 µm, Analytical, (3.0 x 250 mm) 070080
Acclaim PA2, 3 µm Analytical, (4.6 x 50 mm) 063189
Acclaim 120, PA2, 3µm Analytical (4.6 x 100mm) 078001
Acclaim PA2, 3 µm Analytical, (4.6 x 150 mm) 063191
Acclaim PA2, 5 µm Analytical, (4.6 x 150 mm) 063197
Acclaim PA2, 5 µm Analytical, (4.6 x 250 mm) 063199
Guard Columns
Acclaim PA2, 5 µm Guard Cartridges, (4.6 x 10 mm), 2 ea (use V-2 Holder) 069699
Acclaim PA2, 5µm Guard Cartridges (3 x 10mm), 2ea, requires holder 069580 071985
Acclaim PA2, 5µm Guard Cartridges, (2.1 x 10mm), 2 ea; requires holder 069580 069692
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188
Acclaim RSLC PA2 Analytical Columns
Acclaim RSLC PA2, 3 µm Analytical (3.0 x 33 mm) 066276
Acclaim PA2, 3µm Analytical, (3.0 x 50mm) 068973
Acclaim RSLC PA2, 3 µm Analytical (3.0 x 75 mm) 066277
Acclaim PA2, 3 µm Analyitcal (3.0 x 150 mm) 063705
Acclaim RSLC PA2, 2.2µm Analytical, (2.1 x 30mm) 071402
Acclaim RSLC PA2, 2.2µm Analytical (2.1 x 50 mm) 068989
Acclaim RSLC PA2, 2.2µm Analytical (2.1 x 100 mm) 068990
Acclaim RSLC PA2, 2.2µm Analytical, (2.1 x 150mm) 071401
Acclaim RSLC PA2, 2.2µm Analytical (2.1 x 250mm) 074814
Acclaim RSLC PA2, 2.2 µm Analytical, (3.0 x 100mm) 071607
Acclaim RSLC PA2, 2.2 µm Analytical, (3.0 x 50mm) 071608
Acclaim RSLC PA2, 2.2 µm Analytical, (3.0 x 30mm) 071609

应用谱图:

The Acclaim PA2 provides selectivity that is complementary to conventional C18 columns.

 

Omeprazole in anti-heartburn tablet.

 

Determination of energy drink ingredients.

 

Perfluoro-octanoic acid (PFOA) and perfluoro-octanesulfonic (PFOS) acid in tap water.
 

AcclaimPolarAdvantageII(PA2)反相分析柱信息由北京携测技术有限公司为您提供,如您想了解更多关于AcclaimPolarAdvantageII(PA2)反相分析柱报价、型号、参数等信息,欢迎来电或留言咨询。

注:该产品未在中华人民共和国食品药品监督管理部门申请医疗器械注册和备案,不可用于临床诊断或治疗等相关用途