400-6699-1171000

分析测试百科网 认证会员,请放心拨打!

首页> 产品展示> 赛默飞Thermo Acclaim Mixed-Mode HILIC-1 LC Column
非会员

诚信认证:

工商注册信息已核实!

产品分类
友情链接
LC

赛默飞Thermo Acclaim Mixed-Mode HILIC-1 LC Column

品牌 厂商性质 产地 货期
赛默飞 一般经销商 美国 现货

性能特点

液相色谱柱

在线咨询 询底价
AI问答
配套的仪器设备? 可以搭配的相关耗材试剂?
产品介绍

Reversed-Phase and Hydrophilic Interaction Phases Combined on a Single Column

The Acclaim®Mixed-Mode HILIC-1 column utilizes a unique silica-based, mixed-mode stationary phase that combines both reversed-phase (RP) and hydrophilic interaction liquid chromatography (HILIC) properties. The column functional group features a hydrophobic alkyl chain and hydrophilic diol functionality. This combination allows both hydrophobic interaction and hydrophilic interaction to be utilized to optimize separations.

  • Operates in both RP and HILIC modes

  • Retains highly polar molecules

  • Unique selectivity complementary to RP columns

  • Superior performance compared to conventional diol-based columns

  • High efficiency column for high resolution separations

The Acclaim Mixed-Mode HILIC-1 columns consist of 5 μm high-purity, porous, spherical silica with 120 Å-diameter pores bonded with proprietry functional groups, which provide unsurpassed resolution and peak symmetry for a variety of polar and nonpolar molecules.

Wide Range of Applications

The Acclaim Mixed-Mode HILIC-1 column separates both polar and nonpolar molecules with selectivity complementary to RP columns and is suitable for a broad range of applications, including drug metabolites, lipids, polyethylene glycols (PEGs), ethoxylated surfactants and more.


Acclaim Mixed-Mode HILIC-1 ColumnsSpecifications
Particle size:5 µm
Base silica:Spherical, high-purity
Pore size:120 Å
Surface area:300 m2/g
Column chemistry:Proprietary alkyl diol


All the advantages of reversed-phase and HILIC compatibilities in one column.

Note the advantages for reversed-phase and normal-phase modes on a single column.

Separation of phospholipids (lecithin from chicken egg yolk).

Analysis of polyethylene glycols.


Analytical Columns
Acclaim Mixed-Mode HILIC-1, 3µm Analytical (3.0 x 150mm)070090
Acclaim Mixed-Mode HILIC-1, 3µm Analytical (3.0 x 50mm)071912
Acclaim Mixed-Mode HILIC-1, 3µm Analytical (2.1 x 150mm)070091
Acclaim Mixed-Mode HILIC-1, 5 µm (4.6 x 150 mm)066843
Acclaim Mixed-Mode HILIC-1, 5µm (4.6 x 250 mm)066844
Acclaim Mixed-Mode HILIC-1, 5 µm (2.1 x 150 mm)066847
Guard Columns
Acclaim Mixed-Mode HILIC-1, 5 µm Guard Cartrdiges, (4.6 x 10 mm), 2 ea (use V-2 Holder)069706
Acclaim Mixed-Mode HILIC-1, 5µm Guards (3 x 10mm), 2ea, requires holder 069580071913
Acclaim Mixed-Mode HILIC-1, 5µm, Guards (2.1 x 10mm), 2 ea; requires holder 069580069694
Acclaim SST Guard Cartridge Holder V-2069580
Acclaim Guard Kit (Holder and coupler) V-2069707
Guard to Analytical Column Coupler V-2074188


赛默飞Thermo Acclaim Mixed-Mode HILIC-1 LC Column信息由上海希言科学仪器有限公司为您提供,如您想了解更多关于赛默飞Thermo Acclaim Mixed-Mode HILIC-1 LC Column报价、型号、参数等信息,欢迎来电或留言咨询。

注:该产品未在中华人民共和国食品药品监督管理部门申请医疗器械注册和备案,不可用于临床诊断或治疗等相关用途

店铺推荐
  • 品牌:赛默飞
    赛默飞Thermo Cryptand C1 Concentrator Column062893

    赛默飞Thermo Cryptand C1 Concentrator Column062893

    询价
  • 品牌:赛默飞
    赛默飞Thermo Acclaim 120 C8 Reversed-Phase LC Column

    赛默飞Thermo Acclaim 120 C8 Reversed-Phase LC Column

    询价
  • 品牌:赛默飞
    赛默飞Thermo Acclaim C30 Reversed-Phase Column with High Structural Selectivity

    赛默飞Thermo Acclaim C30 Reversed-Phase Column with High Structural Selectivity

    询价
  • 品牌:赛默飞
    赛默飞Thermo Acclaim 120 C18 Reversed-Phase LC Column

    赛默飞Thermo Acclaim 120 C18 Reversed-Phase LC Column

    询价
  • 品牌:赛默飞
    赛默飞Thermo 120 C18 Reversed-Phase LC Column

    赛默飞Thermo 120 C18 Reversed-Phase LC Column

    询价
  • 品牌:赛默飞
    赛默飞Thermo OmniPac PAX-100 Anion-Exchange Column

    赛默飞Thermo OmniPac PAX-100 Anion-Exchange Column

    询价