赛默飞Thermo Acclaim Mixed-Mode HILIC-1 LC Column
品牌 | 厂商性质 | 产地 | 货期 |
---|---|---|---|
赛默飞 | 一般经销商 | 美国 | 现货 |
性能特点
液相色谱柱
Reversed-Phase and Hydrophilic Interaction Phases Combined on a Single Column
The Acclaim®Mixed-Mode HILIC-1 column utilizes a unique silica-based, mixed-mode stationary phase that combines both reversed-phase (RP) and hydrophilic interaction liquid chromatography (HILIC) properties. The column functional group features a hydrophobic alkyl chain and hydrophilic diol functionality. This combination allows both hydrophobic interaction and hydrophilic interaction to be utilized to optimize separations.
Operates in both RP and HILIC modes
Retains highly polar molecules
Unique selectivity complementary to RP columns
Superior performance compared to conventional diol-based columns
High efficiency column for high resolution separations
The Acclaim Mixed-Mode HILIC-1 columns consist of 5 μm high-purity, porous, spherical silica with 120 Å-diameter pores bonded with proprietry functional groups, which provide unsurpassed resolution and peak symmetry for a variety of polar and nonpolar molecules.
Wide Range of Applications
The Acclaim Mixed-Mode HILIC-1 column separates both polar and nonpolar molecules with selectivity complementary to RP columns and is suitable for a broad range of applications, including drug metabolites, lipids, polyethylene glycols (PEGs), ethoxylated surfactants and more.
Acclaim Mixed-Mode HILIC-1 ColumnsSpecifications | |
---|---|
Particle size: | 5 µm |
Base silica: | Spherical, high-purity |
Pore size: | 120 Å |
Surface area: | 300 m2/g |
Column chemistry: | Proprietary alkyl diol |
All the advantages of reversed-phase and HILIC compatibilities in one column.
Note the advantages for reversed-phase and normal-phase modes on a single column.
Separation of phospholipids (lecithin from chicken egg yolk).
Analysis of polyethylene glycols.
Analytical Columns | |
---|---|
Acclaim Mixed-Mode HILIC-1, 3µm Analytical (3.0 x 150mm) | 070090 |
Acclaim Mixed-Mode HILIC-1, 3µm Analytical (3.0 x 50mm) | 071912 |
Acclaim Mixed-Mode HILIC-1, 3µm Analytical (2.1 x 150mm) | 070091 |
Acclaim Mixed-Mode HILIC-1, 5 µm (4.6 x 150 mm) | 066843 |
Acclaim Mixed-Mode HILIC-1, 5µm (4.6 x 250 mm) | 066844 |
Acclaim Mixed-Mode HILIC-1, 5 µm (2.1 x 150 mm) | 066847 |
Guard Columns | |
---|---|
Acclaim Mixed-Mode HILIC-1, 5 µm Guard Cartrdiges, (4.6 x 10 mm), 2 ea (use V-2 Holder) | 069706 |
Acclaim Mixed-Mode HILIC-1, 5µm Guards (3 x 10mm), 2ea, requires holder 069580 | 071913 |
Acclaim Mixed-Mode HILIC-1, 5µm, Guards (2.1 x 10mm), 2 ea; requires holder 069580 | 069694 |
Acclaim SST Guard Cartridge Holder V-2 | 069580 |
Acclaim Guard Kit (Holder and coupler) V-2 | 069707 |
Guard to Analytical Column Coupler V-2 | 074188 |
赛默飞Thermo Acclaim Mixed-Mode HILIC-1 LC Column信息由上海希言科学仪器有限公司为您提供,如您想了解更多关于赛默飞Thermo Acclaim Mixed-Mode HILIC-1 LC Column报价、型号、参数等信息,欢迎来电或留言咨询。
注:该产品未在中华人民共和国食品药品监督管理部门申请医疗器械注册和备案,不可用于临床诊断或治疗等相关用途