400-6699-1175223

分析测试百科网 认证会员,请放心拨打!

首页> 产品展示> Acclaim Phenyl-1 Unique Reversed-Phase Column with High Aromatic Selectivity

诚信认证:

工商注册信息已核实!

LC Columns

Acclaim Phenyl-1 Unique Reversed-Phase Column with High Aromatic Selectivity

品牌 厂商性质 产地 货期
赛默飞 一般经销商 美国 订货

询底价
产品介绍

Reversed-Phase Column with High Aromatic Selectivity for the Separation of Aromatic Compounds

Acclaim®Phenyl-1 columns provide unique selectivity for aromatic compounds while maintaining sufficient hydrophobic interaction and aqueous compatibility for superior chromatographic performance.

Acclaim Phenyl-1 is based on covalent modification of high-purity, spherical, porous silica particles, with a specially designed silane ligand-bearing proprietary alkyl aromatic functionality. This novel column chemistry results in the following benefits.

  • High aromatic selectivity

  • High hydrophobic retention

  • Unique and complementary selectivity

  • Compatibility with highly aqueous mobile phase

  • High efficiency and rugged packing

Acclaim Phenyl-1 columns are available in 3 μm particle sizes and 4.6, 3.0, and 2.1 mm diameters, with an average pore diameter of 120 Å. Acclaim Phenyl-1 columns may be used for LC/MS applications.

Applications

The Acclaim Phenyl-1 column has a unique bonded phase which has both enhanced aromatic selectivity and high hydrophobicity compared to other commercial phenyl-type phases, including biphenyl, diphenyl, C6-phenyl and C3-phenyl phases. It is also compatible with aqueous mobile phases. These capabilities make this column ideal for a broad range of applications including drug development and testing in which analytes commonly contain rings, conjugation, and ring substituents.


Acclaim Phenyl-1: Designed for the Analysis of Aromatic CompoundsSpecifications
Column ChemistryProprietary alkyl phenyl
End-cappedYes
Particle Size3 µm
Average pore diameter120Å
Surface area300 m2/g
pH range2–8
Temperature<60°C
Starting materialUltrapure silica
Particle shapeSpherical



Separation of glucocorticosteroids


Separation of estrogens


Separation of fat-soluble vitamins


Analysis of soybean lecithin and egg lecithin


The National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 869a is useful for characterizing liquid chromatographic (LC) column selectivity for separation of PAHs.

These separations demonstrate that the Acclaim Phenyl-1 column shows different and complementary selectivity to other reversed-phase columns.


Analytical Columns
Acclaim Phenyl-1, 3µm, Analytical, (4.6 x 150mm)071969
Acclaim Phenyl-1, 3µm, Analytical, (4.6 x 100mm)078017
Acclaim Phenyl-1, 3µm, Analytical, (3.0 x 150mm)071970
Acclaim Phenyl-1, 3µm, Analytical, (3.0 x 100mm)074693
Acclaim Phenyl-1, 3µm, Analytical, (3.0 x 50mm)071972
Acclaim Phenyl-1, 3µm, Analytical, (3.0 x 250mm074694
Acclaim Phenyl-1, 3µm, Analytical, (2.1 x 250mm)078014
Acclaim Phenyl-1, 3µm, Analytical, (2.1 x 150mm)071971
Acclaim Phenyl-1, 3µm, Analytical, (2.1 x 100mm)078015
Acclaim Phenyl-1, 3µm, Analytical, (2.1 x 50mm)078016
Guard Columns
Acclaim Phenyl-1, 3µm, Guard (4.6x10mm)071973
Acclaim Phenyl-1, 3µm, Guard (3.0x10mm)071974
Acclaim Phenyl-1, 3µm Guard (2.1x10mm)079934
Acclaim SST Guard Cartridge Holder V-2069580
Acclaim Guard Kit (Holder and coupler) V-2069707
Guard to Analytical Column Coupler V-2074188


Acclaim Phenyl-1 Unique Reversed-Phase Column with High Aromatic Selectivity信息由上海希言科学仪器有限公司为您提供,如您想了解更多关于Acclaim Phenyl-1 Unique Reversed-Phase Column with High Aromatic Selectivity报价、型号、参数等信息,欢迎来电或留言咨询。

注:该产品未在中华人民共和国食品药品监督管理部门申请医疗器械注册和备案,不可用于临床诊断或治疗等相关用途