性能特点
离子色谱IC柱
For the Analysis of Fluoride and Other Inorganic Anions
The IonPac®AS14 is designed for fast analysis of the common inorganic anions in diverse sample matrices.
Common inorganic anions are resolved in 13 minutes using an isocratic carbonate/bicarbonate eluent.
Sodium tetraborate gradient optimizes difficult separations.
The AS14 column meets or exceeds US EPA Method 300.0 (A) performance requirements.
The AS14 supports the separation of inorganic anions, including fluoride, chloride, nitrite, bromide, nitrate, phosphate, and sulfate using a carbonate/bicarbonate eluent coupled with suppressed conductivity detection. With the AS14, inorganic anions can be determined easily in drinking water, wastewater, foods and beverages, scrubber solutions, and other diverse sample matrices.
For simplified operation, use the AS14 Eluent Concentrate and the Combined Seven Anion Standard. Use the Anion Self-Regenerating Suppressor (ASRS 300) with the AS14 column for low-noise operation.
Note: See also the IonPac AS22, the latest column recommended for fast analysis of inorganic anions.
IonPac AS14 Anion-Exchange Column Specifications | |
---|---|
Dimensions | IonPac AS14 Analytical Column: 2×250 mm and 4×250 mm IonPac AG14 Guard Column: 2×50 mm and 4×50 mm |
Maximum operating pressure | 27.6 MPa (4000 psi) |
Mobile phase compatibility | pH 2–12; 0–100% HPLC solvents |
Substrate characteristics | Bead Diameter: 9 µm Pore Size: 100 Å Cross-Linking (%DVB): 55% |
Functional group characteristics | Ion-Exchange Group: Surface-functionalized alkyl quaternary ammonium ion Hydrophobicity: Medium High |
Capacity | 16 µeq (2×250 mm analytical column) 65 µeq (4×250 mm analytical column) |
Column construction | PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic. |
The IonPac AS14 column is ideal for interference-free determination of inorganic anions, including fluoride, in drinking water.
Separation of weakly retained anions using a sodium tetraborate gradient elution.
Determination of anionic counterions present in a gel permeation purified peptide.
Isocratic separation of inorganic anions on an IonPac AS14 column in less than 13 minutes.
Analytical Columns | |
---|---|
IonPac AS14 Analytical Column (4 x 250 mm) | 046124 |
IonPac AS14 Analytical Column (2 x 250 mm) | 046129 |
Guard Columns | |
---|---|
IonPac AG14 Guard Column (4 x 50 mm) | 046134 |
IonPac AG14 Guard Column (2 x 50 mm) | 046138 |