400-6699-1171000

分析测试百科网 认证会员,请放心拨打!

首页> 产品展示> 赛默飞Thermo Dionex IonPac AS16 Hydroxide-Selective Anion-Exchange Column离子色谱IC柱
非会员

诚信认证:

工商注册信息已核实!

产品分类
友情链接
IC

赛默飞Thermo Dionex IonPac AS16 Hydroxide-Selective Anion-Exchange Column离子色谱IC柱

品牌 厂商性质 产地 货期
赛默飞 一般经销商 美国 现货

性能特点

离子色谱IC柱

在线咨询 询底价
AI问答
配套的仪器设备? 可以搭配的相关耗材试剂?
产品介绍

High-Capacity Column Optimized for Determination of Polarizable Anions

The Thermo Scientific™ Dionex™ IonPac™ AS16 column is ideally suited for trace perchlorate in drinking water in accordance with US EPA Methods 314.0 and 314.1 (Primary Method). The Dionex IonPac AS16 column simplifies the determination of polarizable anions, including thiosulfate, iodide, thiocyanate, and perchlorate using an isocratic hydroxide eluent.

  • Separate hydrophobic anions (iodide, thiocyanate, and thiosulfate) in less than 20 min

  • Can be used for trace perchlorate in drinking water matrices

  • Ideal for polyvalent anions, including polyphosphates and polycarboxylates

  • Ultralow hydrophobicity allows fast analysis of polarizable anions

The Dionex IonPac AS16 is a high-capacity, hydroxide-selective column for the determination of polarizable anions in a variety of sample matrices. Trace concentrations of perchlorate in drinking water, surface water, and ground water matrices can easily be determined using a large-loop injection. The Dionex IonPac AS16 column is available in three formats: standard bore (4 × 250 mm), microbore (2 × 250 mm) and capillary (0.4 × 250 mm). The capillary format is packed with the same material as the equivalent standard bore and microbore versions (providing the same performance as a 4 mm and 2 mm column) but requires only 1/100th the eluent flow rate. The capillary format provides the advantage of significantly reduced eluent consumption, which helps reduce operating costs. The Dionex IonPac AS16 capillary column is used in the second dimension of the 2D-IC method for the analysis of trace perchlorate (sub ppb) in drinking water.

Note: Also see the Dionex IonPac AS20, with complementary selectivity for confirmation of perchlorate identification when using EPA Method 314.1


Dionex IonPac AS16 Anion-Exchange Column Specifications
Dimensions

Dionex IonPac AS16 Analytical Column:
2×250 mm and 4×250 mm
Dionex IonPac AG16 Guard Column:
2×50 mm and 4×50 mm
Dionex IonPac AS16 Capillary Column:
0.4 × 250 mm
Dionex IonPac AG16 Capillary Guard Column:
0.4 × 50 mm

Maximum operating pressure4000 psi
Mobile phase compatibilitypH 0–14; 0–100% HPLC solvents
Substrate characteristicsBead Diameter: 9 µm
Pore Size: 2000 Å super macroporous resin
Cross-Linking (%DVB): 55%
Latex characteristicsFunctional Group: Alkanol quaternary ammonium ion
Latex Cross-Linking: 1%
Latex Diameter: 80 nm
Hydrophobicity: Ultralow
Capacity42.5 µeq (2×250 mm analytical column)
0.875 µeq* (2× 50 mm guard column)
170 µeq (4×250 mm analytical column)
3.5 µeq* (4×50 mm guard column)
1.7 µeq (0.4 × 250 mm capillary column)
0.035 µeq (0.4 × 50 mm capillary guard column)
*Guards are packed with a low capacity microporous resin
Column constructionPEEK™ with 10-32 threaded ferrule style end fittings.
All components are nonmetallic.



2D-IC analysis of trace perchlorate using the Dionex IonPac AS20 Microbore column and the Dionex IonPac AS16 Capillary column.

Isocratic separation of inorganic anions and hydrophobic anions using the Dionex IonPac AS16 Capillary column.

Gradient separation of inorganic anions and polyphosphates using the Dionex IonPac AS16 Capillary column.

Analysis of low level perchlorate using a large loop injection on the Dionex IonPac AS16 Capillary column.

Isocratic separation of polarizable anions and inorganic anions using a sodium hydroxide eluent on the 4mm Dionex IonPac AS16 column.

Determination of trace perchlorate in drinking water using the Dionex IonPac AS16 column.

Determination of polarizable anions and inorganic anions using a potassium hydroxide gradient delivered with an EG using the 4 mm Dionex IonPac AS16 column.

Separation of polyphosphates on the 4 mm Dionex IonPac AS16 column using a potassium hydroxide gradient delivered with an Eluent Generator.


Analytical Columns
IonPac AS16 Analytical Column (4 x 250 mm)055376
IonPac AS16 Analytical Column (2 x 250 mm)055378
Dionex IonPac AS16 Capillary Column (0.4 x 250 mm)082315
Guard Columns
IonPac AG16 Guard Column (4 x 50 mm)055377
IonPac AG16 Guard Column (2 x 50 mm)055379
Dionex IonPac AG16 Capillary Guard Column (0.4 × 50 mm)082316


赛默飞Thermo Dionex IonPac AS16 Hydroxide-Selective Anion-Exchange Column离子色谱IC柱信息由上海希言科学仪器有限公司为您提供,如您想了解更多关于赛默飞Thermo Dionex IonPac AS16 Hydroxide-Selective Anion-Exchange Column离子色谱IC柱报价、型号、参数等信息,欢迎来电或留言咨询。

注:该产品未在中华人民共和国食品药品监督管理部门申请医疗器械注册和备案,不可用于临床诊断或治疗等相关用途

店铺推荐
  • 品牌:赛默飞
    赛默飞Thermo Acclaim Trinity P1 Series

    赛默飞Thermo Acclaim Trinity P1 Series

    询价
  • 品牌:赛默飞
    赛默飞Thermo Acclaim Trinity P2 LC Column

    赛默飞Thermo Acclaim Trinity P2 LC Column

    询价
  • 品牌:赛默飞
    赛默飞Thermo Acclaim 300 C18 Protein and Peptide Column

    赛默飞Thermo Acclaim 300 C18 Protein and Peptide Column

    询价
  • 品牌:赛默飞
    赛默飞Thermo IonPac NS1 Reversed-Phase LC Column

    赛默飞Thermo IonPac NS1 Reversed-Phase LC Column

    询价
  • 品牌:赛默飞
    赛默飞Thermo Acclaim Rapid Separation LC (RSLC) Column

    赛默飞Thermo Acclaim Rapid Separation LC (RSLC) Column

    询价
  • 品牌:赛默飞
    赛默飞Thermo PolarAdvantage Reversed-Phase LC Column

    赛默飞Thermo PolarAdvantage Reversed-Phase LC Column

    询价