400-6699-1171000

分析测试百科网 认证会员,请放心拨打!

首页> 产品展示> 赛默飞Thermo GlycanPac AXH-1 Glycan Analysis Column离子色谱IC柱
非会员

诚信认证:

工商注册信息已核实!

产品分类
友情链接
IC

赛默飞Thermo GlycanPac AXH-1 Glycan Analysis Column离子色谱IC柱

品牌 厂商性质 产地 货期
赛默飞 一般经销商 美国 现货

性能特点

离子色谱IC柱

在线咨询 询底价
AI问答
配套的仪器设备? 可以搭配的相关耗材试剂?
产品介绍

GlycanPac AXH-1 Columns for the High-Resolution Separation and Analysis of Glycans

The Thermo ScientificGlycanPacAXH-1 column is a high-performance, silica-based HPLC column for simultaneous separation of glycans by charge, size, and polarity. It is designed for high-resolution and high-throughput analysis with unique selectivity for biologically important glycans, either labeled or native, by LC-fluorescence and LC-mass spectrometry (MS) methods.

The GlycanPac AXH-1 column can be used for qualitative, quantitative, and structural characterization of uncharged and charged glycans present in biological molecules (e.g., proteins).

Features:

  • Unique glycan selectivity based on charge, size, and polarity

  • Excellent resolution for both native and labeled glycans

  • Useful for both high-resolution glycan profile characterization and easy quantification of glycans based on charge

  • Compatible with fluorescence and MS detection methods

  • High chromatographic efficiency and excellent column stability

The GlycanPac AXH-1 column, based on innovative mixed-mode surface chemistry, combines both weak anion-exchange (WAX) and hydrophilic interaction liquid chromatography (HILIC) retention mechanisms for optimal selectivity and resolution power. The WAX functionality provides retention and selectivity for negatively charged glycans, while the HILIC mode facilitates the separation of glycans of the same charge according to their polarity and size. As a result, the GlycanPac AXH-1 column provides unparalleled capabilities for glycan separations. Additionally, this column offers charge-based separations for various glycans without discrimination of size and polarity, making it a suitable tool for accurate quantification of glycans which cannot be achieved with other HPLC columns. The GlycanPac AXH-1 column is designed and tested for LC-fluorescence detection and LC-MS applications using volatile aqueous buffers (e.g., ammonium acetate or ammonium formate) and acetonitrile.

GlycanPac AXH-1 columns are based on high-purity and spherical silica substrates in both 1.9 and 3 µm sizes for UHPLC and standard HPLC applications, respectively. GlycanPac AXH-1 columns are available in various dimensions for applications with different resolutions, throughput, and instrument requirements.


GlycanPac AXH-1 Column Specifications
Column Dimensions

1.9 μm: 2.1 × 250mm, 2.1 × 150mm, 2.1 ×100mm

3 μm: 4.6 × 150mm, 3.0 × 150mm, 2.1 × 150mm

Bead SizeSpherical 1.9 μm, 3 μm particles
SubstrateHigh-purity, Porous, Spherical Silica


Functional GroupWAX and HILIC Mixed-Mode
Recommended Flow Rate Range:

1.9 μm: 0.1 to 0.4 mL/min. for: all 2.1 mm columns

3 μm: 0.6 to 1.2 ml/min for 4.6 × 150 mm

0.3 to 0.6 ml/min for 3.0 × 150 mm

0.1 to 0.5 ml/min. for 2.1 × 150 mm

Pressure Limit

1.9 μm: 7,000 psi for 2.1 × 100mm,

10,000 psi for 2.1 ×150mm

15,000 psi for 2.1 × 250mm

3 μm: 6,000 psi for all 3 μm columns

Temperature Range:Ambient to 60 ºC
pH Range2.0 - 8.0


The GlycanPac AXH-1 column can be used for qualitative, quantitative, and structural characterization of uncharged and charged glycans present in biological molecules. The glycan elution profile consists of a series of peaks grouped into several "clusters" in which the neutral glycans elute first, followed by mono-sialylated, di-sialylated, tri-sialylaled species.Analytes in each cluster, retained by anion exchange interactions, represents the glycans of the same charge. Within each cluster the glycans having the same charge are further separated according to their sizes and polarity by HILIC interaction.

Similar separation ofN-glycans using a 3µm packing material with Fluorescence detection.

Separation ofN-glycans using the GlycanPac AXH-1, 1.9µm packing with LC/MS detection.

Accurate and easy quantitative analysis of relative amounts of glycans of each charge state is possible by using a modified gradient.

Separation of human IgG using the GlycanPac AXH-1, 1.9µm column.


Analytical Columns
GlycanPac AXH-1, 3 µm, Analytical (4.6x150mm)082468
GlycanPac AXH-1, 3 µm, Analytical (3.0x150mm)082469
GlycanPac AXH-1, 3 µm, Analytical (2.1x150mm)082470
GlycanPac AXH-1, 1.9 µm, Analytical (2.1x250mm)082521
GlycanPac AXH-1, 1.9 µm, Analytical (2.1x150mm)082472
GlycanPac AXH-1, 1.9 µm, Analytical (2.1x100mm)082473
GlycanPac AXH-1, 1.9 µm, Analytical (1.0 × 150 mm, with nanoViper)164863
Guard Columns
GlycanPac AXH-1, 3 µm, Guard (4.6x10 mm) 2ea (Use Holder V-2)082474
GlycanPac AXH-1, 3 µm, Guard (3.0x10 mm) 2ea (Use Holder V-2)082475
GlycanPac AXH-1, 3 µm, Guard (2.1x10 mm) 2ea (Use Holder V-2)082476
Acclaim SST Guard Cartridge Holder V-2069580
Acclaim Guard Kit (Holder and coupler) V-2069707
Guard to Analytical Column Coupler V-2074188


赛默飞Thermo GlycanPac AXH-1 Glycan Analysis Column离子色谱IC柱信息由上海希言科学仪器有限公司为您提供,如您想了解更多关于赛默飞Thermo GlycanPac AXH-1 Glycan Analysis Column离子色谱IC柱报价、型号、参数等信息,欢迎来电或留言咨询。

注:该产品未在中华人民共和国食品药品监督管理部门申请医疗器械注册和备案,不可用于临床诊断或治疗等相关用途

店铺推荐
  • 品牌:赛默飞
    赛默飞Thermo Acclaim Trinity P1 Series

    赛默飞Thermo Acclaim Trinity P1 Series

    询价
  • 品牌:赛默飞
    赛默飞Thermo Acclaim Trinity P2 LC Column

    赛默飞Thermo Acclaim Trinity P2 LC Column

    询价
  • 品牌:赛默飞
    赛默飞Thermo Acclaim 300 C18 Protein and Peptide Column

    赛默飞Thermo Acclaim 300 C18 Protein and Peptide Column

    询价
  • 品牌:赛默飞
    赛默飞Thermo IonPac NS1 Reversed-Phase LC Column

    赛默飞Thermo IonPac NS1 Reversed-Phase LC Column

    询价
  • 品牌:赛默飞
    赛默飞Thermo Acclaim Rapid Separation LC (RSLC) Column

    赛默飞Thermo Acclaim Rapid Separation LC (RSLC) Column

    询价
  • 品牌:赛默飞
    赛默飞Thermo PolarAdvantage Reversed-Phase LC Column

    赛默飞Thermo PolarAdvantage Reversed-Phase LC Column

    询价